COMMISSION DECISION (EU) 2020/1804
of 27 November 2020
establishing the EU Ecolabel criteria for electronic displays
(notified under document C(2020) 8156)
(Text with EEA relevance)
Article 1
Article 2
Article 3
Article 4
Article 5
Article 6
Article 7
Article 8
ANNEX
EU Ecolabel criteria for awarding the EU Ecolabel to electronic displays
FRAMEWORK
Aims of the criteria
EU ECOLABEL CRITERIA
Criterion 1 – Energy consumption
1.1
Energy savings
1.2
Power management
Criterion 2 – Restricted substances
2.1
Excluded or limited substances
| Group 1 hazards | ||||||||||
| 
 
 | ||||||||||
| Group 2 hazards | ||||||||||
| 
 
 
 
 
 | ||||||||||
| Group 3 hazards | ||||||||||
| 
 
 
 | 
2.1(a)
Restrictions on Substances of Very High Concern (SVHCs)
| Printed Circuit Boards (Printed Wiring Boards, populated motherboards, power boards (power supply units) and module boards ) >10 cm2 | 
| Electrical wiring/cables (aggregated) | 
| External cables (Power cable (AC and DC power cords), modem cable and LAN cable if applicable, HDMI cable and RCA cable) | 
| External housing (Back cover, front cover (bezel decoration) and stands) | 
| External housing of remote control | 
| LED backlights (LED arrays) | 
2.1(b)
Restrictions on the presence of specific substances
| Substance group | Scope of restriction (substances and sub-assemblies/component parts) | Concentration limits (where applicable) | |||||||||||||||||||||||||||||||||||
| 
 | Exemption 8b in accordance with Directive 2011/65/EU of the European Parliament and of the Council(8)relating to the use of cadmium in electrical contacts shall not be permitted. | 0,01 % w/w Test method: IEC 62321-5 | |||||||||||||||||||||||||||||||||||
| 
 | The following organotin stabiliser compounds classified with Group 1 and 2 hazards shall not be present in external cables: 
 
 
 
 
 
 | n/a | |||||||||||||||||||||||||||||||||||
| External housing of the display shall not contain the following colourants: Azo dyes that may cleave to the carcinogenic aryl amines listed in Appendix 8 of the Regulation (EC) No 1907/2006, and/or Colourant compounds included in the IEC 62474 declarable substances list. | n/a | ||||||||||||||||||||||||||||||||||||
| Polycyclic Aromatic Hydrocarbons (PAHs) classified with Group 1 and 2 hazards shall not be present at concentrations greater than or equal to individual and sum total concentration limits in any external plastic or man-made rubber surfaces of: External cables External housing of the remote control Rubber parts of the remote control The presence and concentration of the following PAHs shall be verified: PAHs restricted by the Regulation (EC) No 1907/2006: 
 
 
 
 
 
 
 
 Additional PAHs subject to restriction: 
 
 
 
 
 
 
 
 
 
 | The individual concentration limits for PAHs restricted under Regulation (EC) No 1907/2006 shall be 1 mg/kg The sum total concentration limit for the 18 listed PAHs shall not be greater than 10 mg/kg Test method: AfPS GS 2014:01 PAK. | ||||||||||||||||||||||||||||||||||||
| 
 | Biocidal products intended to provide an anti-bacterial function shall not be incorporated into External housing and rubber parts of the remote control. | n/a | |||||||||||||||||||||||||||||||||||
| 
 | Exemption 3 in accordance with Directive 2011/65/EU relating to the use of mercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) shall not be permitted. | n/a | |||||||||||||||||||||||||||||||||||
| 
 | Arsenic and its compounds shall not be used in the manufacturing of LCD display unit glass and screen cover glass. | 0,0050 % w/w | |||||||||||||||||||||||||||||||||||
| 
 | Plastic parts >25 g must not contain chlorinated polymers. Note: For this specific sub-requirement, plastic cable housing is not considered as a ‘plastic part’. | n/a | |||||||||||||||||||||||||||||||||||
| 
 | Diisononyl phthalate (DINP), Diisodecyl phthalate (DIDP) shall not be used in external power cables. | n/a | 
2.1(c)
Restrictions on substances classified under Regulation (EC) No 1272/2008
| Parts containing flame retardants | ||||||
| 
 
 
 | ||||||
| Parts containing plasticisers | ||||||
| 
 
 
 | 
Derogations for the use of hazardous flame retardants and plasticisers
| Substance /mixture type | Applicability | Derogated hazard class, category and hazard statement code and derogation conditions | 
| Flame retardants | Printed Circuit Boards | Flame retardants classified with Group 3 hazards and TBBPA (classified with Group 2) are derogated for use. | 
| External cables | Flame retardant and its synergist classified with Group 3 hazard and Antimony trioxide (Sb2O3) classified with Group 2 hazards are derogated for use. | |
| External housing of the display | Flame retardants and their synergists classified with Group 2 and 3 hazards are derogated for use. | |
| Plasticisers | External cables, internal electrical wiring and external housing of the display | Plasticisers classified with Group 3 hazards are derogated for use. |