Vorherige Seite
    Regulation No 1 of the Economic Commission for Europe of the United Nations (... (42010X0710(01))
    1 - 250 - 51
    Nächste Seite
    EU - Rechtsakte: 11 External relations

    h-h: horizontal plane

    passing through focus of headlamp

    v-v: vertical plane

    C.   Measuring points of illumination values

    [Bild bitte in Originalquelle ansehen]
    Note: Figure shows the measuring points for right-hand traffic. Points 7 and 8 move to their corresponding location at the right-hand side of the picture for left-hand traffic.

    ANNEX 7

    Requirements for lamps incorporating lenses of plastic material — testing of lens or material samples and of complete lamps

    1.   GENERAL SPECIFICATIONS

    1.1.   The samples supplied pursuant to paragraph 2.2.4 of this Regulation shall satisfy the specifications indicated in paragraphs 2.1 to 2.5 below.
    1.2.   The two samples of complete lamps supplied pursuant to paragraph 2.2.3 of this Regulation and incorporating lenses of plastic material shall, with regard to the lens material, satisfy the specifications indicated in paragraph 2.6 below.
    1.3.   The samples of lenses of plastic material or samples of material shall be subjected, with the reflector to which they are intended to be fitted (where applicable), to approval tests in the chronological order indicated in table A reproduced in appendix 1 to this annex.
    1.4.   However, if the lamp manufacturer can prove that the product has already passed the tests prescribed in paragraphs 2.1-2.5 below, or the equivalent tests pursuant to another Regulation, those tests need not be repeated; only the tests prescribed in appendix 1, table B, shall be mandatory.

    2.   TESTS

    2.1.   Resistance to temperature changes

    2.1.1.   Tests

    Three new samples (lenses) shall be subjected to five cycles of temperature and humidity (RH = relative humidity) change in accordance with the following programme:
    3 hours at 40 °C ± 2 °C and 85-95 % RH;
    1 hour at 23 °C ± 5 °C and 60-75 % RH;
    15 hours at – 30 °C ±2 °C;
    1 hour at 23 °C ± 5 °C and 60-75 % RH;
    3 hours at 80 °C ± 2 °C;
    1 hour at 23 °C ± 5 °C and 60-75 % RH.
    Before this test, the samples shall be kept at 23 °C ± 5 °C and 60-75 % RH for at least four hours.
    Markierungen
    Leseansicht
    Verwendung von Cookies.

    Durch die Nutzung dieser Website akzeptieren Sie automatisch, dass wir Cookies verwenden. Cookie-Richtlinie

    Akzeptieren